Our answer
On our planning profile the Anker SOLIX C1000 Gen 2 runs a box fan for about 14 hours, or 11 hours if you keep a reserve back.
The checks behind this answer
Stored energy is the final check, not the first. Voltage, continuous output, and startup demand must clear before runtime means anything. Missing published evidence stays marked unverified instead of being treated as a pass.
| Check | Result | Why |
|---|---|---|
| Voltage | Clears | A box fan runs on 120V and the Anker SOLIX C1000 Gen 2 supplies 120V AC. |
| Continuous output | Clears | A 60W running load sits inside the 2,000W continuous rating, leaving about 3233% headroom. |
| Startup demand | Clears | The 120W start is covered by continuous output alone, so no surge rating is needed. |
| Inverter self-consumption | Unverified | This is a long, low-power load, so the inverter's own draw materially changes the answer. That figure is not published for this station. |
How the number is built
A battery holds back some of its rated capacity, and converting to household AC costs more on top. Of the 1,024Wh rated here, roughly 811Wh reaches the outlet under a conservative planning model.
That energy meets an average load of 60W, which applies a 100% duty cycle to a 60W running draw. Holding back a 20% reserve for battery age, cold, and a longer outage leaves 11 hours. These are calculations, not measurements from a test.
What we could not verify
These gaps are in the published evidence, not in the arithmetic. Each one is a reason to check before you depend on this pairing.
- Inverter self-consumption is not published, and it matters more than the appliance load on a run this long.
Replace our assumptions with your own
Fan speed is the whole story. Running a box fan on low instead of high can roughly halve the energy it uses over a night.
Read the nameplate or data label for voltage and rated amps or watts, then run the appliance through a normal cycle on a plug-in energy meter for 24 hours. Use the measured watt-hours in the calculator instead of the default on this page.
Continue through this cluster
Use the next page that answers your unresolved constraint
Evidence used on this page
Important fields are tied to a specific source. Manufacturer claims, government guidance, calculations, and planning assumptions remain separate.
- C1000 Gen 2 product specifications
Anker SOLIX US
US page. Capacity, output, peak, input, weight, UPS, and charging claims checked.
official product page
- Portable power station collection
Anker SOLIX US
Official US collection page. Current direct C1000 Gen 2 price checked.
official product page
- C1000 Gen 2 battery support record
Anker SOLIX Support
Battery chemistry and cycle-retention claim checked.
official support
- Calculation and compatibility methodology
Power Station Station
Defines the capacity, efficiency, reserve, duty-cycle, voltage, continuous-output, and startup checks applied across the site. Planning defaults are visible on every page that uses them.
planning assumption
- C1000 Gen 2 published specification table
Anker SOLIX US
US product page specification table, including the banded MPPT current limits of 8.2A from 11V to 28V and 14.5A from 29V to 60V.
official product page