Our answer
On our planning profile the EcoFlow DELTA Pro 3 runs a pellet stove for about 27 hours, or 21 hours if you keep a reserve back.
The checks behind this answer
Stored energy is the final check, not the first. Voltage, continuous output, and startup demand must clear before runtime means anything. Missing published evidence stays marked unverified instead of being treated as a pass.
| Check | Result | Why |
|---|---|---|
| Voltage | Clears | A pellet stove runs on 120V and the EcoFlow DELTA Pro 3 supplies 120V AC. |
| Continuous output | Clears | A 150W running load sits inside the 4,000W continuous rating, leaving about 2567% headroom. |
| Startup demand | Clears | The 450W start is covered by continuous output alone, so no surge rating is needed. |
How the number is built
A battery holds back some of its rated capacity, and converting to household AC costs more on top. Of the 4,096Wh rated here, roughly 3,244Wh reaches the outlet under a conservative planning model.
That energy meets an average load of 121W, which applies a 80% duty cycle to a 150W running draw. Holding back a 20% reserve for battery age, cold, and a longer outage leaves 21 hours. These are calculations, not measurements from a test.
Before you rely on this
These limits decide whether this appliance belongs on a portable battery at all.
- A pellet stove needs power to stop safely, not only to keep producing heat. The combustion blower must keep moving exhaust while the fire dies down.
- Follow the backup method your stove manufacturer approves. Some manufacturers treat a standard UPS as a safe-shutdown device only, not a way to keep heating.
- Most pellet stove control boards require a pure sine wave supply.
Replace our assumptions with your own
The ignition cycle is short but it is the highest load the stove presents. Sizing from the steady blower draw alone will underestimate what the stove needs at the moment it lights.
Meter a complete cycle from cold ignition through steady heating, if your stove manufacturer permits metering. Record the peak as well as the average.
Continue through this cluster
Use the next page that answers your unresolved constraint
Evidence used on this page
Important fields are tied to a specific source. Manufacturer claims, government guidance, calculations, and planning assumptions remain separate.
- DELTA Pro 3 published specifications
EcoFlow US
Capacity, output, surge, voltage, chemistry, cycle life, solar inputs, weight, UPS, expansion, and warranty checked.
official product page
Distinguishes safe shutdown from continued operation and documents tested 700W, 750W, and 1,000W inverter/charger options.
official support
- Calculation and compatibility methodology
Power Station Station
Defines the capacity, efficiency, reserve, duty-cycle, voltage, continuous-output, and startup checks applied across the site. Planning defaults are visible on every page that uses them.
planning assumption